Introduction
Corrosion of a twin pipe culvert under the M606 in West Yorkshire had compromised its structural integrity. Due to the location, length, construction and configuration, several contractors had declined National Highways’ attempts to renovate the ‘significant structure’ over the years, having found it too difficult to do. A collaborative approach by Carnell and trenchless specialists OnSite brought engineering solutions through ECI. This problem-solving approach continued during the construction phase, to successfully remediate the 160m long culvert with 1570mm diameter pipes. The scheme received praise from the local community and client which contributed to it winning the CECA Yorkshire & The Humber Project of the Year Award in 2025.
Early Contractor Involvement
ECI identified several challenges:
– Pipe length and circumference meant the liners would need UV curing. This technique can’t negotiate corners, so excavation of the bend was required.
– Corrosion of the corrugated steel pipes meant voids, while asbestos coated bolts couldn’t be cut.
– The inlet and outlet locations with nearby gas main and buried services required imaginative solutions to minimise the impact on the local community.