Cyclical Maintenance
Our Technology & Lighting team self-deliver network testing of streetlighting for Maintenance & Response contractor Amey, on the National Highways East Midlands network.
Over the last year we have surveyed approximately 1700 assets (columns and feeder pillars), undertaking the following:
Structural tests
Column inspections using a MEWP to check brackets and lamp integrity.
We use a TVC ColcheK2 to undertake non-destructive testing of the below ground section of the planted steel lighting column. An ultrasonic thickness gauge (dip test) is applied at a depth of 400mm to determine the thickness of the column material and identify signs of rusting / corrosion.
Electrical tests
For column electrical testing we carry out a full periodic test on ALL circuits as per BS7671 18th edition. This includes dead testing (insulation resistance, continuity, polarity) and then the live tests (earth loop impedance, PFC, R1&R2).
At the feeder pillar we take ZE readings , check and record supply characteristics , check and verify schematic drawing information and BS7671 testing on hard wired equipment within the pillar (light, heater and RCD socket).